3103 Isolated Repeater
-
|
|
- Isolation / 1:1 repetition of 0…20 mA
- Response time < 7 ms (patent pending)
- Accuracy < ±0.05%
- Supply via power rail or terminals
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3104 Isolated converter
-
|
|
- Isolation / conversion of standard DC signals
- Power supply and signal isolator for 2-wire transmitters
- Response time < 7 ms (patent pending)
- 2-wire supply > 17 V @ 20 mA
- Accuracy < ±0.05%
- Supply via power rail or terminals
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3105 Isolated converter
-
|
|
- Isolation / conversion of standard DC signals
- Ultra low cost
- Response time < 7 ms (patent pending)
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
|
-
3108 Isolated repeater / splitter
-
|
|
- Isolation / 1:1 repetition of 0…20 mA
- Splitter function: 1 in - 2 out
- Responstime < 7 ms (patent pending)
- Accuracy < ±0.05% (patent pending)
- Supply via power rail or terminals
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3109 Isolated converter / splitter
-
|
|
- Isolation / conversion of standard DC signals
- Power supply and signal isolator for 2-wire transmitters
- Splitter function: 1 in - 2 out. Individual setup of each output
- 2-wire supply > 17 V @ 20 mA
- Response time < 7 ms (patent pending)
- Accuracy < ±0.05% (patent pending)
- Supply via power rail or terminals
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3185 Loop-powered isolator
-
|
|
- Isolation / 1:1 repetition of 0/4…20 mA
- Loop-powered input
- 1 or 2 channels
- Response time < 5 ms
- Drop voltage: < 1.2 V
- Accuracy< ±0.1%
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3114 Isolated universal converter
-
|
|
- Conversion / isolation of analogue signals
- Power supply and signal isolator for 2-wire transmitters
- In: 2-, 3- and 4-wire
- Response time 0.4 / 1,0 s
- 2-wire supply > 15 V @ 20 mA
- Accuracy < ±0.1% (patent pending)
- Programmable via display 4501 and adapter 4590
Internal CJC
- Supply via power rail or terminals
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
-
3186 2-wire transmitter isolator
-
|
|
- Isolation / 1:1 repetition of 4…20 mA
- 2-wire input
- 1 or 2 channels
- Response time < 5 ms
- Drop voltage: < 2.5 V
- Accuracy < +/- 0.1%
- Factory-calibrated measurement ranges
- Polarity-protected terminals and supply
- I.S. approvals: FM Div. 2, ATEX zone 2, IECEx zone 2
|
|